Availability: | |
---|---|
WHY6380S
POWEAM
Parameters
21 reportable Parameters+3 histograms: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW- -CV, RDW- SD, PLT, MPV, PDW, PCT,P-LCR,P-LCC, Lym#, MID#, GRAN#, LYM%, MID%, GRAN%, WBC/RBC/PLT histograms
Performance
Parameter
| Precision
| Linear Range | Contamination Rate
|
WBC
| ≤2.0% (3.5-15.0x109)/L
| (0-100.0x109)/L
| ≤0.5% .
|
RBC
| ≤1.5% (3.0-6.0x1012)/L
| (0.10- -8.00x1012)/L
| ≤0.5%
|
HGB
| ≤1.5% (100-180)g/L
| (0- -250)g/L
| ≤0.6% .
|
MCV
| ≤1.0% (70- 120)fL
| ||
PLT
| ≤4.0% (150- -500x109)/L
| (0-1000x109)/L
| ≤1.0% .
|
Sample Volume
Prediluted: 20μL
Whole blood: 9μL
Throughput
60 samples per hour
Display:10.4 inch color LCD display, touchscreen
Storage
Up to 50,000 results including histograms, and patient information
Compatibility
Build-in thermal printer
External laser printer or inkjet printer
4 USB, 1 L AN support protocol HL7 and compatible with LIS system
Environment
Working Voltage: AC 100V~240V, 50~60Hz
Rated power: 40- -60VA
Working Temperature: 10°C~40C
Relative humidity: 20%- 85%
Reagent
DILUENT 20L
Build-in LYSE 500ML
CLEANER 50ML (Optional)
Power Requirement
AC100V-240V 50Hz/60Hz ≤300VA
Dimension and Weight
Dimension: Depth(400 mm) × width(285 mm) × height(400 mm)
Weight:≤20Kg
Parameters
21 reportable Parameters+3 histograms: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW- -CV, RDW- SD, PLT, MPV, PDW, PCT,P-LCR,P-LCC, Lym#, MID#, GRAN#, LYM%, MID%, GRAN%, WBC/RBC/PLT histograms
Performance
Parameter
| Precision
| Linear Range | Contamination Rate
|
WBC
| ≤2.0% (3.5-15.0x109)/L
| (0-100.0x109)/L
| ≤0.5% .
|
RBC
| ≤1.5% (3.0-6.0x1012)/L
| (0.10- -8.00x1012)/L
| ≤0.5%
|
HGB
| ≤1.5% (100-180)g/L
| (0- -250)g/L
| ≤0.6% .
|
MCV
| ≤1.0% (70- 120)fL
| ||
PLT
| ≤4.0% (150- -500x109)/L
| (0-1000x109)/L
| ≤1.0% .
|
Sample Volume
Prediluted: 20μL
Whole blood: 9μL
Throughput
60 samples per hour
Display:10.4 inch color LCD display, touchscreen
Storage
Up to 50,000 results including histograms, and patient information
Compatibility
Build-in thermal printer
External laser printer or inkjet printer
4 USB, 1 L AN support protocol HL7 and compatible with LIS system
Environment
Working Voltage: AC 100V~240V, 50~60Hz
Rated power: 40- -60VA
Working Temperature: 10°C~40C
Relative humidity: 20%- 85%
Reagent
DILUENT 20L
Build-in LYSE 500ML
CLEANER 50ML (Optional)
Power Requirement
AC100V-240V 50Hz/60Hz ≤300VA
Dimension and Weight
Dimension: Depth(400 mm) × width(285 mm) × height(400 mm)
Weight:≤20Kg
UK: 419 Harborne Road, Edgbaston, Birmingham, England.
+86-25-86703826
+86-25-86727065
+86-18915970836
Copyright © 2020 Poweam Medical