Availability: | |
---|---|
FM-10B
POWEAM
Ctg Machine Maternal Fetal Maternal Monitor Fetal Monitor Twins Maternal Fetal Monitor
Below is the information:
Horizontal type, portable & compact. Advanced streamline outline design.
Applicable for real-time morning of prenatal, childbirth and postpartum.
Comply with China & international standard.
Foldable handle & portable, all-in-one probe holder
Display: 12.1 inch foldable color TFT LCD screen
Calculation and display of auto/manual fetal movement
The color of parameters and waveforms settable as per user's preference
At least 24 hours CTG data storage, selectable review and print after power off.
25mm/s high speed printing of stored CTG data.
Print-speed Selectable: 1cm/mincm/mincm/minmm/sec
Alarm reviewable
Auto/manual patient ID generation, easy user-management & data searching.
Audio and visual alarm, lightness and volume are adjustable.
Alarm & remark are available for probe moving and abnormal condition.
America and China 2 Standards print function
Display/offset print of Twins FHR (fetal heart rate) waveform
3 display mode: Fetal, fetal and maternal, maternal, either mother or fetal emphasis morning selectable
Real-time print and timing print
Event remark function
Built-in rechargeable high energy battery
The printer's buffer, selectable and auto shutdown printing are available.
Independent network function, support remote, wireless, wired mixed central monitor network
Optional maternal monitoring function.
FM-10B FHR1, TOCO, FM
FM-10B Plus FHR1, TOCO, FM, maternal ECG, NIBP, SpO2, TEMP, RESP
Optional FHR2, FW(Fetal wakeing), Wireless network
FHR (Fetal heart rate) | Ultrasound frequency | 1MHz± 1KHz |
Measurement range | 30~240bpm | |
Resolution | ± 1bpm | |
Alarm & accuracy | Up limit (30~240)bpm,± 5% | |
Lower limit | (30~240)bpm,± 5% | |
TOCO | Range | 0~100% |
Resolution | 1% | |
Zero-mode | Manual. 5, 10, 15, 20 TOCO base-line adjustable | |
Pressure measure accuracy | 7% | |
Fetal movement | Manual and auto fetal movement mark | |
Auto fetal movement waveform | ||
Wide-line printer | ||
Printer paper | Foldable Z-type thermal paper | |
Width | 110mm/152mm | |
Printing speed | 1cm/min, 2cm/min, 3cm/min and fast buffer printing of 25cm/sec | |
Power supply | 100~240VAC, 50/60Hz | |
Fetal mode | Fetal/maternal mode | |
Maternal mode | ||
Model Function Configure |
Ctg Machine Maternal Fetal Maternal Monitor Fetal Monitor Twins Maternal Fetal Monitor
Below is the information:
Horizontal type, portable & compact. Advanced streamline outline design.
Applicable for real-time morning of prenatal, childbirth and postpartum.
Comply with China & international standard.
Foldable handle & portable, all-in-one probe holder
Display: 12.1 inch foldable color TFT LCD screen
Calculation and display of auto/manual fetal movement
The color of parameters and waveforms settable as per user's preference
At least 24 hours CTG data storage, selectable review and print after power off.
25mm/s high speed printing of stored CTG data.
Print-speed Selectable: 1cm/mincm/mincm/minmm/sec
Alarm reviewable
Auto/manual patient ID generation, easy user-management & data searching.
Audio and visual alarm, lightness and volume are adjustable.
Alarm & remark are available for probe moving and abnormal condition.
America and China 2 Standards print function
Display/offset print of Twins FHR (fetal heart rate) waveform
3 display mode: Fetal, fetal and maternal, maternal, either mother or fetal emphasis morning selectable
Real-time print and timing print
Event remark function
Built-in rechargeable high energy battery
The printer's buffer, selectable and auto shutdown printing are available.
Independent network function, support remote, wireless, wired mixed central monitor network
Optional maternal monitoring function.
FM-10B FHR1, TOCO, FM
FM-10B Plus FHR1, TOCO, FM, maternal ECG, NIBP, SpO2, TEMP, RESP
Optional FHR2, FW(Fetal wakeing), Wireless network
FHR (Fetal heart rate) | Ultrasound frequency | 1MHz± 1KHz |
Measurement range | 30~240bpm | |
Resolution | ± 1bpm | |
Alarm & accuracy | Up limit (30~240)bpm,± 5% | |
Lower limit | (30~240)bpm,± 5% | |
TOCO | Range | 0~100% |
Resolution | 1% | |
Zero-mode | Manual. 5, 10, 15, 20 TOCO base-line adjustable | |
Pressure measure accuracy | 7% | |
Fetal movement | Manual and auto fetal movement mark | |
Auto fetal movement waveform | ||
Wide-line printer | ||
Printer paper | Foldable Z-type thermal paper | |
Width | 110mm/152mm | |
Printing speed | 1cm/min, 2cm/min, 3cm/min and fast buffer printing of 25cm/sec | |
Power supply | 100~240VAC, 50/60Hz | |
Fetal mode | Fetal/maternal mode | |
Maternal mode | ||
Model Function Configure |
UK: 419 Harborne Road, Edgbaston, Birmingham, England.
+86-25-86703826
+86-25-86727065
+86-18915970836
Copyright © 2020 Poweam Medical