Availability: | |
---|---|
WHY6180
Poweam
Automatic Fully Hematology Analyzer (WHY6180)
Below is parameter:
Using digital filtering, Blood cells overlap calibration, fitting curve, Floating landmark technology, etc,
enhanced accurate and reliable result
Perfect quality control function
Boasts management system for quality control, 9 kinds of control files.
Mean value, SD value, CV value are provided, Automatic drawing L-J graph. Provide matched blood control
Automated Maintenance
Automated washing during power on and power off, reducing the blockage rate
Fan Shape door for easy maintenance
Automatic storing 40,000 samples with all parameters and 3 histograms, 2G SD card is available
Cyanide-free environmental Reagent
Using cyanide-free environmental hemolytic reagent to test HGB, it is safe and environmental.
Easy operation
Colorful Windows interface, no need connecting computer.
Operating by graphic button with mouse and keyboard
Parameters | WBC, LYM#, MID#, GRAN#,LYM%,MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, PCT, RDW-CV, RDW-SD, MPV, PDW, P-LCR and Histograms for WBC, RBC and PLT |
Calibration | manual calibration, automatic calibration, fresh blood calibration |
Cross contamination rate | WBC,RBC,HGB<0.5%, PLT<1% |
Aperture parameter | 3-Part Differential leukocytecount, 20parameters and 3 histograms. |
Sample consumption | Whole blood ≤9.6µL, capillary blood ≤9.6µL, prediluted capillary blood ≤20µL. |
Counting mode | Whole blood and prediluted |
Display | 10.4" TFT LCD display |
Throughput | 35samples/hr |
Reagent | POWEAM reagents OR Open systems are optional |
Power supply | 100~244VAC 50/60Hz |
Power | 180W |
Communication | RS-232C serial port |
Environment requirement | ambient temperature 0-40, relative humidity 85% |
Automatic Fully Hematology Analyzer (WHY6180)
Below is parameter:
Using digital filtering, Blood cells overlap calibration, fitting curve, Floating landmark technology, etc,
enhanced accurate and reliable result
Perfect quality control function
Boasts management system for quality control, 9 kinds of control files.
Mean value, SD value, CV value are provided, Automatic drawing L-J graph. Provide matched blood control
Automated Maintenance
Automated washing during power on and power off, reducing the blockage rate
Fan Shape door for easy maintenance
Automatic storing 40,000 samples with all parameters and 3 histograms, 2G SD card is available
Cyanide-free environmental Reagent
Using cyanide-free environmental hemolytic reagent to test HGB, it is safe and environmental.
Easy operation
Colorful Windows interface, no need connecting computer.
Operating by graphic button with mouse and keyboard
Parameters | WBC, LYM#, MID#, GRAN#,LYM%,MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, PCT, RDW-CV, RDW-SD, MPV, PDW, P-LCR and Histograms for WBC, RBC and PLT |
Calibration | manual calibration, automatic calibration, fresh blood calibration |
Cross contamination rate | WBC,RBC,HGB<0.5%, PLT<1% |
Aperture parameter | 3-Part Differential leukocytecount, 20parameters and 3 histograms. |
Sample consumption | Whole blood ≤9.6µL, capillary blood ≤9.6µL, prediluted capillary blood ≤20µL. |
Counting mode | Whole blood and prediluted |
Display | 10.4" TFT LCD display |
Throughput | 35samples/hr |
Reagent | POWEAM reagents OR Open systems are optional |
Power supply | 100~244VAC 50/60Hz |
Power | 180W |
Communication | RS-232C serial port |
Environment requirement | ambient temperature 0-40, relative humidity 85% |
UK: 419 Harborne Road, Edgbaston, Birmingham, England.
+86-25-86703826
+86-25-86727065
+86-18915970836