ICU Patient Defibrillator Monitoring

Availability:
  • DM7000

  • Poweam

Poweam DM7000 AED biophasic defibrillator with monitor function can meet all of your clinical request from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS).

Specifications for defibrillator
Display
Display Type 7 inch high resolution LCD display
Sweep Speed 25mm/sec
Information HR, Lead/Pads, On/Off Alarm , SpO2,
 AED Functions and Prompts,
 Alarm Selection and Limits, Delivered Energy.
Below is feature
Waveform Biphasic
Charge Time Less than 7 seconds with a new fully charged battery.
Energy Display Monitor display indicates both selected and delivered energy.
Charge Prompt Type Voice and visual prompts.
Electrode Impedance Measurement Range 0-250 ohms.
ECG Monitoring for Defibrillator
Patient Connection 5-lead ECG cable, or 3-lead ECG cable, paddles.
Lead Selection Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.
ECG Size 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.
Heart Rate 20-300BPM.
Heart Rate Alarm On/Off displayed on monitor, user-selectable.
Smart Alarms Beeper/voice prompts indicate shockable rhythm.
SpO2 Module
Measurement Range 30~100%, 
± 2% between 80%~90%,
 others ± 5%
Alarm Range User set high limit and low limit.
Alarm Accuracy ± 10% within setting values.
Alarm time Accuracy Less than 12 sec.
Recorder
Paper 50mm thermal.
Speed 12.5mm/sec, 25mm/sec, 50mm/sec. 
 User-selectable 6-second delay.
Printing Method High-resolution, thermal print head.
Print-out Modes Manual or automatic, user-configurable.
On/Off Control Front panel and paddle.
Automatic Function 9-seconds recording initiated by alarm activation or 
defibrillator charge or defibrillator discharge.
Battary
Type Rechargeable, Ni-MH battery, 12V.
Operating Time For a new, fully charged 
battery60 defibrillator discharges at maximum energy, 
or 3 hours minimum of continuous ECG monitoring.
 Additional parameters will effect operating time with different functions.
AED Mode
AED Function Auto analyze and charge X3 with programmable auto energy level selection, 
 screen prompts, and voice prompts.
Shockable Rhythms Ventricular fibrillation with amplitude >=200UV, 
 ventricular tachycardia with rates >=140bpm,
 and QRS complex wave duration >=140ms.
Charge Control Control on device front panel, press key on paddle.
Prompts Voice and visual prompts.
Manual Mode
Energy Selection Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.
Synchronized Mode Synchronizes defibrillator pulse to patient's R-wave. 
"SYNC" message displayed on monitor


 

ModelDM7000
Brief Introductionbiophasic AED defibrillator,7" LCD
Patient Monitor
ECG,HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts,
Alarm Selection and Limits, Delivered Energy.


Previous: 
Next: 

QUICK LINK

PRODUCT CATEGORIES

GET IN TOUCH

China: No.18 Fenghua Road,Yuhua Economic Development Zone, Nanjing City, Jiangsu Province, China
 

UK: 419 Harborne Road, Edgbaston, Birmingham, England.

+86-25-86703826

+86-25-86727065

+86-18915970836

GET FREE ENQUIRY NOW!

Contact us

Copyright © 2020 Poweam Medical