Vet CI-2000B Veterinary Infusion Pump with Drug Library

1. Complies with IEC 60601, high safety designation with dual CPUs.
2. High brightness LCD display and user- friendly operation interface.
3. Easy switch among d/min, mL/h and volume/time units.
4. Available for Bolus mode.
5. Anti- reverse function on motor to prevent upstream.
6. Self-check when start up and during infusion.
7. Top pressure sensor for preventing underflow.
8. Pressure and air-in-line detection devices both with 8 sensitivities setting,dynamically display pressure value.
9. IV set management function: Up to 20 IV sets can be added, stored and deleted in memory, convenient for operation after calibration.
10. Adjustable 8 volume levels of alarm for convenient operation in different environments.
11.Waterproof model, drug library is optional.
Availability:
  • CI-2000B

  • Poweam

Veterinary Infusion Pumps Physical Attributes
Height126.1cm -146.1cm
Depth57.7cm
Width99.8cm
Weigh82kg
Veterinary Infusion Pumps Hood Specifications
Access door size18 x 13cm
Tubing access ports10
Mattress to hood height 48.0mm
Soft bed mattress size L*W*H 73.6cm x38.6cm x1.8cm
Mattress tilt ±12 °
Drawer size 28.0cm x 24.7cm and 28.0cm x 11.3cm(2pcs)
Drawer depth 36.0cm
Infusion Pumps Temperature Control Modes
Tem. control modeSkin & air temperature control mode
Air mode control temp. range20° C-37° C
Air mode control override temp. range37° C-39° C
Air mode control accuracy≤±1.0°C
Skin mode control temp. range34° C-37° C
Skin mode control override temp. range37° C-38° C
Skin temp. accuracy ±0.3°C
With Dual-skin temp. monitoring
Veterinary Infusion Pumps Performance
Air flow velocity across mattress< 10 cm/sec
Temp. rise time at 22 °C (72 °F) ambient<20min (From 22 °C,50% RH,to 35 °C)                              
Temp. variability< 0.3°C
Temp. overshoot< 0.5 °C maximum
Temp. uniformity with a level mattress< 0.5°C
Operating noise level in hood≤45dBa
Carbon Dioxide (CO2) Level<0.5%
CI-2000B Infusion Pumps Servo Humidity Option
Humidity control operating time without refilling24hours
Humidity control range30%-95% RH
Humidity display accuracy±5%RH
Humidity control accuracy±5% RH
Humidity control reservoir capacity1500ml
CI-2000B Infusion Pumps Servo Oxygen Option
Oxygen control accuracy of full scale± 2%
Oxygen control range21 % to 65%
Oxygen display accuracy (21% calibration)± 5%
Oxygen display accuracy (100% calibration)± 3%
Oxygen display resolution1%
Veterinary Infusion Pumps Scale Option
Weight range300g to 8000g
Weight display resolution1 g
Weight accuracy±10 g
CI-2000B Infusion Pumps Operating Environment
Temperature20° to 30° C
Humidity10 to 95% RH
Air VelocityUpto 0.3 m/sec
 Infusion Pumps Storage/Shipping Information
Temperature -26° to 60° C
Humidity0 to 96% RH

Relevant products: 

veterinary infusion pumpVeterinary syringe pumpveterinary anesthesia machine 
veterinary patient monitor veterinary ecg machineveterinary hematology analyzer
veterinary chemistry analyzerveterinary Elisa readerveterinary electrolyte analyzer
veterinary defibrillatorveterinary operation tableveterinary x-ray
docking station,double channel infusion pumpdouble channel syringe pump
veterinary syringe pumphorizonal infusion pumpveterinary feeding pump


Previous: 
Next: 

QUICK LINK

PRODUCT CATEGORIES

GET IN TOUCH

China: No.18 Fenghua Road,Yuhua Economic Development Zone, Nanjing City, Jiangsu Province, China
 

UK: 419 Harborne Road, Edgbaston, Birmingham, England.

+86-25-86703826

+86-25-86727065

+86-18915970836

GET FREE ENQUIRY NOW!

Contact us

Copyright © 2020 Poweam Medical